EMERGENCY
SLIDE-OUT RETRACTION
(ROOMS, GENERATORS, STORAGE COMPARTMENTS)
ML44100BX_SO

Operator Information – EMERGENCY MANUAL OPERATION
Slide-Out Identification & Room Style (A/B)
Adjustment Information
Chain Link / Roller Information
Control Panel / Control Box Information
Control Unit (aka Manifold Assembly) Information
Cylinder Information
Diagnostics Information (Flow Charts)
Electrical Information
Hose Information
Hydraulic Diagrams (Connection / Flow / Schematic)
Installation & Pre-Installation Information
Operator Information – EMERGENCY MANUAL OPERATION
Operation Information – Normal Operation
Performance Issues (Creeping, etc.)
Pump & Power Unit Information
Relay Information
Seal Information (Hydraulic Seals & Environmental Seals)
Snap Ring Information
Stop Pad & Bearing Plate Information
Switch Information (Pressure / Force-Activated / etc.)
Valve Information (Solenoid Valve, Rack Sensing Valve, Check Valve, etc.)
Sales Material (Brochures & Videos)

SLIDE-OUT IDENTIFICATION & STYLE

Click to Link
• System Identification (Pictorial & Nomenclature)
plus Link to Brochures & Videos
ML17785_01_NOM_PR.HTML
• System Styles (Type A/B Identification) mi158331

ADJUSTMENT INFORMATION

Click to Link
• Room Adjustment
– “Lateral Arm” Slide-Out Systems
– “Lateral Arm with Torsional Tube” Slide-Out
mi152002
• Room Adjustment
– “Vertical Arm” Slide-Out
ML18751
• Room Adjustment
– “X-Slide” Slide-Out
mi154560
• Room Adjustment (Product / Service Bulletin
– 11OCT14)
– “X-Slide” Slide-Out
– 2004 Winnebago® Motorhomes
mi9556

CHAIN LINK / ROLLER INFORMATION

Click to Link
• Chain Link / Roller Replacement
– Locating Solenoid Valves (mi150068)
– Disassembly & Assembly (mi150069)
– “X-Slide” Slide-Outs
– “Universal
– (USO) (ULO) (UPLO) ( ULI/ULO)” Slide-Outs (All slide-out systems that start with “Universal")
ml36149
• Roller Replacement Location Identification
– X-Slide
– Lateral Arm
– Universal
mi15535c

CONTROL PANEL / CONTROL BOX INFORMATION

Click to Link
• Control Panel
– Templates/Cut-Outs
ml44100b1_ctrlpnl.html
• Control Panel (for Slide-Outs)
– Electrical Connection Diagram
mp840500
• Weather Resistant Switch Box
– Installation Instructions
mi159412

CONTROL UNIT (aka Manifold Assembly) INFORMATION

Click to Link
• Control Unit Electrical Connection Diagram
– Room 1
– Room 2
– Room 3
mp840400

CYLINDER INFORMATION

Click to Link
“Synchronizing” Cylinders
• Synchronizing Cylinder Synchronizing Procedure
– for Setup/Repair of Slide-Outs with Synchronizing Cylinders
ml39247
• Synchronizing Cylinder Replacement Procedure
– for ALL Slide-Outs with Two Cylinders and a Synchronizing Cylinder
– includes Hose Assembly Replacement Procedure
ML21970
• Bleeding Procedure for Remote Manifolds and/or Synchronizing Cylinders with Valving. Mi9564
• “Synchronizing” Cylinder
– Synchronizing/Bleed Procedure
– for “Universal Straight-Out Light Duty (USOLD)” Slide-Out
– Remote Manifold
– Synchronizing Cylinders with Valving
ml51267
• Synchronizing Cylinder Replacement
– for “Universal Platform Level Out (UPLO)"
– with Synchronizing Cylinder with Solenoid Valves
ML57137
mp445001
mp445501
Cylinders
• Cylinder
– Seal Replacement Instructions
MI1583
• Cylinder Replacement
– for “Four Cylinder” Slide-Out
ML21058
• Cylinder Replacement
– for “Four Cylinder” Slide-Out
– No Leveling System / Reversible Pump
ML18759
• Cylinder Replacement/Bleeding Instructions
– for “Four Cylinder” Slide-Out
– No Leveling System / Reversible Pump
ML18781
• Cylinder Replacement
– for “Guided” Slide-Out with Special Washers
mi15200j
• Cylinder
– Replacement Instructions
– for “Guided” Slide-Out with Room Extension Manifold
ML19524
• Cylinder Replacement
– for “Lateral Arm” Slide-Out
ML30248
• Cylinder Replacement
– for “Level-Out (LO)” Slide-Out (Old name: “Flat Floor")
ML23518
• Cylinder Replacement
– for “Rail with HWH® Rack Sensing Valve” Slide-Out
MP459415
• Cylinder
– Replacement Instructions
– for “Rail with HWH® Synchronizing Cylinder” Slide-Out
ML16463
• Cylinder Replacement
– for “Rail with HWH® Synchronizing Cylinder” Slide-Out
– No Leveling System / Reversible Pump
ML19241
• Cylinder Replacement
– for “Single Cylinder” Slide-Out
MP459412
• Cylinder Replacement
– for “Train Drive” Slide-Out
ML23527
• Cylinder Replacement
– for “Universal Platform Level Out (UPLO)” Slide-Out
– with Synchronizing Cylinder with Solenoid Valves
ML57135
• Cylinder Replacement
– for “Vertical Arm” Slide-Out
ML18750
• Cylinder Replacement
– for “Vertical Arm” Slide-Out
– No Leveling System / Reversible Pump
ML18702

DIAGNOSTICS INFORMATION

Click to Link
• Trouble-Shooting Flow Chart
– Chinook RV Trail Wagons® Slide-Out Functions
(HWH® 2000 Series)
Page 1 of 2 mi957290
Page 2 of 2 mi957291

ELECTRICAL INFORMATION

Click to Link
• General Electrical Connection Protection ml44100b1_elec.html

HOSE INFORMATION

Click to Link
• Hose General Information (Swaging,Tightening, Warranties & Returns) ml44100b1_hose.html
• Hose Swage Leaks (Product / Service Bulletin
– 12FEB03)
– HWH® Slide-Out Systems
mi9551
• Hose Swage Leaks
– (Product / Service Bulletin
– 06FEB03)
– HWH® / Winnebago® Slide-Outs
mi9550

HYDRAULIC DIAGRAMS (Connection / Flow / Schematic)

Generic & OEM-Specific Diagrams ml56050.html
• Hydraulic Line Connection Diagram
– Slide-Out Room Extension Connections at Manifold
mp648490
• Hydraulic Line Connection Diagram
– “Universal Level-In/Level-Out (ULI/ULO)” Slide-Out
mp648325
• Hydraulic Line Connection Diagram
– “Universal Level-Out (ULO)” Slide-Out
mp648301
• Hydraulic Line Connection Diagram
– “Universal Platform Level-Out (UPLO)” Slide-Out
mp648325
• Hydraulic Line Connection Diagram
– “Universal Straight-Out (USO)” Slide-Out
mp648290
Generic Hydraulic Line Connection Diagrams
BECAUSE THERE CAN BE CHANGES TO SYSTEM COMPONENTS, DRAWINGS LISTED HERE MAY DIFFER FROM EXISTING EQUIPMENT ON A PARTICULAR VEHICLE. IF NECESSARY, CONTACT HWH CORPORATION FOR ASSISTANCE. (See also genericdiagrams3.html)
“Guided” ML50388
“In Floor” ML50390
“Rail” ML50389
Single cylinder ML50387
“Universal Straight-Out (USO) ML50391
“Universal Straight-Out Light Duty (OSOLD) ML50392
“Universal Level-Out (ULO) with Room Lift Cylinders ML50393
“Universal Level-Out (ULO) with Room Lift cylinders & Center Lift Cylinders ML50394
“Universal Platform Level-Out (UPLO) with one Platform Lift Cylinder ML50395
“Universal Platform Level-Out (UPLO) with two Platform Lift Cylinders ML50529
“Universal Platform Level-Out (UPLO)” with three platform lift cylinders ML50530
“Universal Platform Level-Out (UPLO)” with synchronizing cylinder box and three platform lift cylinders ML50531
“Universal Level-In/Level-Out (ULI/ULO)” with one floor lift cylinder ML50532
Manifold hydraulic connection diagram
– 2 power extend/power retract jacks
– 2 room extensions
– auxiliary hand pump
MP642470

INSTALLATION & PRE-INSTALLATION INFORMATION

Click to Link
• Pre-Installation Information
– CAUTION Maximum Hose Length Chart for Synchronizing Cylinder Systems
Under Construction
• Installation Video
– “Universal Level-Out (ULO)” Slide-Out
ml32486b.wmv
• Installation Video
– “Universal Level-Out (ULO)” Slide-Out
ml32486c.wmv

OPERATION INFORMATION – NORMAL OPERATION

Click to Link
• Operator Manuals ml44100b0_op_mls.html
• “Rail with Rack Sensing Valve” Slide-Out
(aka Newell® Phantom Suite®)
mi150010

OPERATION INFORMATION – EMERGENCY MANUAL OPERATION

• Manual Slide-Out Operation
– General Information
MP349490
• Hand-Pump Slide-Out System Operation (ML49509) MP349907
• Hand-Pump System Priming Procedure MP440015
• Slide-Out (Room or Generator)
– Pump/Manifold with Solenoid Valves
– Nut Release or Flipper Cam Release Valves
– Manual Retraction Winch
MP349500
• Slide-Out (Room or Generator)
– Pump/Manifold with Solenoid Valves w/T-Handle Valve Release
– Manual Retraction Winch
MP359490
• Slide-Out (Room or Generator)
– Reversible Pump with Emergency Retract Valve w/T-Handle Valve Release
– Retract Tube
– Manual Retraction Winch
MP359440
• Slide-Out (Room or Generator)
– Reversible Pump with Emergency Retract Valve
– Manual Retraction Winch
MP359472
• Slide-Out (Room or Generator)
– Synchronizing Cylinder with Integrated Solenoid Valve Manifold
– ________________ Release Valves
– Manual Retraction Winch
MP349498
• “Level Out ______________” Slide-Out
– Pump/Manifold with Small (1.5" DIA) Solenoid Valves
– Nut Release or Flipper/Cam Release Valves
– Manual Retraction Bolt
MP349553
• “Rail with HWH® Rack Sensing Valve” Slide-Out
– WITHOUT ROOM RETRACTION WINCH.
MP359410
• “Straight-Out or Level Out (Angle Mount) ______” Slide-Out
– Pump/Manifold with Small (1.5" DIA) Solenoid Valves
– Nut Release or Flipper/Cam Release Valves
– Manual Retraction Bolt
MP349551
• “Universal Level In/Level Out (ULI/ULO)” Slide-Out
PG 1– MANUAL FLOOR LIFT PROCEDURE
PG 2– MANUAL SLIDE-OUT RETRACT PROCEDURE
– No Slide-Out Locks
– One Set of Valves for the Floor-Lift and Slide-Out
Located on the Pump/Manifold
– Nut Release or Flipper/Cam Release Valves
– Floor-Lift: Square Torsion Shaft
– Slide-Out: Threaded Retraction Rods
ML49809
mp349573
mp349574
• “Universal Level In/Level Out (ULI/ULO)” Slide-Out
PG 1– MANUAL FLOOR LIFT PROCEDURE
PG 2– MANUAL SLIDE-OUT RETRACT PROCEDURE
– No Slide-Out Locks
– One Set of Valves for the Floor-Lift and Slide-Out
Located on Pump/Manifold
– Nut Release or Flipper/Cam Release Valves
– Floor-Lift: Splined Torsion Shaft
– Slide-Out: Threaded Retraction Rods
ML49810
mp349575
mp349576
• “Universal Level In/Level Out (ULI/ULO)” Slide-Out
PG 1– MANUAL FLOOR LIFT PROCEDURE
PG 2– MANUAL SLIDE-OUT RETRACT PROCEDURE
– No Slide-Out Locks
– One Set of Valves for the Floor-Lift and Slide-Out
Located on Synchronizing Cylinder
– Floor-Lift: Splined Torsion Shaft
– Slide-Out: Threaded Retraction Rods
ML52671
mp349575a
mp349576a
• “Universal Level Out (ULO)” Slide-Out System
PG 1– MANUAL SLIDE-OUT PLATFORM LIFT PROCEDURE
PG 2– MANUAL SLIDE-OUT RETRACT PROCEDURE
– Small Solenoid Valves Located on Pump/Manifold
– Nut Release or Flipper/Cam Release Valves
– Platform-Lift: Manual Lift Bolts
– Slide-Out: Threaded Retraction Rods
ML36687
mp34956c
mp34956d

• “Universal Level Out (ULO)” Slide-Out
PG 1– MANUAL SLIDE-OUT PLATFORM LIFT PROCEDURE
PG 2– MANUAL SLIDE-OUT RETRACT PROCEDURE
– Small Solenoid Valves Located on Synchronizing Cylinder
– Platform-Lift: Manual Lift Bolts
– Slide-Out: Threaded Retraction Rods

ML54108
mp349563
mp349564
• One “Universal Level Out (ULO)” Slide-Out WITH JACKS
PG 1– MANUAL JACK OPERATION
PG 2– MANUAL SLIDE-OUT OPERATION
– Pump Run Toggle Switch
ml46786
mi953603
mi953604
• Two “Universal Level Out (ULO)” Slide-Outs WITH JACKS
PG 1– MANUAL JACK OPERATION
PG 2– MANUAL SLIDE-OUT OPERATION
– Pump Run Toggle Switch
ml46787
mi953605
mi953606
• Three “Universal Level Out (ULO)” Slide-Outs WITH JACKS
PG 1– MANUAL JACK OPERATION
PG 2– MANUAL SLIDE-OUT OPERATION
– Pump Run Toggle Switch
ml46788
mi953607
mi953608
• Four “Universal Level Out (ULO)” Slide-Outs WITH JACKS
PG 1 – MANUAL JACK OPERATION

PG 2 – MANUAL SLIDE-OUT OPERATION
– Pump Run Toggle Switch
ml46789
mi953609
mi953610
• “Universal Platform Level-Out (UPLO)” (EARLY STYLE) Slide-Out
PG 1 – MANUAL SLIDE-OUT PLATFORM LIFT PROCEDURE
PG 2 – MANUAL SLIDE-OUT RETRACT PROCEDURE
– Small Solenoid Valves Located on Slide-Out Control Manifold
– Nut Release or Flipper/Cam Release Valves
– Platform-Lift: Manual Lift Bolts
– Slide-Out: Threaded Retraction Rods
ml49443
mp349559a
mp349561a
• “Universal Platform Level Out (UPLO)” (CURRENT STYLE) Slide-Out
PG 1 – MANUAL SLIDE-OUT PLATFORM LIFT PROCEDURE
PG 2 – MANUAL SLIDE-OUT RETRACT PROCEDURE
– Small Solenoid Valves Located on Slide-Out Control Manifold
Located on Synchronizing Cylinder
– Flipper/Cam Release Valves
– Platform-Lift: Manual Lift Bolts
– Slide-Out: Threaded Retraction Rods
ML52670
mp349559b
mp349561b
• “Universal Straight Out” (EARLY STYLE) Slide-Out
– Small Solenoid Valves
– Nut Release or Flipper/Cam Release Valves
– Threaded Retraction Rods
MP349556
• “Universal Straight Out” (CURRENT STYLE) Slide-Out
– Small Solenoid Valves
– Nut Release or Flipper/Cam Release Valves
– Threaded Retraction Rods
MP349558
• “Universal Straight Out” (CURRENT STYLE) Slide-Out
– Small Solenoid Valves Located on Synchronizing Cylinder
– Flipper/Cam Release Valves
– Threaded Retraction Rods
MP349580A
• “X-Slide” Slide-Out
– Small Solenoid Valves Located on Pump/Manifold
– Nut Release or Flipper/Cam Release Valves
– Threaded Retract Rods
MP349554
• “X-Slide” Slide-Out
– Reversible Pump with Emergency Retract Valve & Retract Tube
– Threaded Retraction Rods
MP35954C

PERFORMANCE ISSUES (Creeping)

Click to Link
• Product / Service Bulletin (28AUG95)
– Creeping
– Diagnosing Slide-Out Rooms “Creeping” Issues
– Type “A” Slide-Outs with Large Solenoid Valves
mi9546
• Test Procedures for Room Cylinder Creep (MI158330/8331) ml42737

PUMP & POWER UNIT INFORMATION

Click to Link
• General Pump & Power Unit Information ml44100b1_pwrunit.html

RELAY INFORMATION

Click to Link
• Relay Connections
– Pump & Safety Relay Electrical Connections
mp840450
• Relay Re-Wiring (Product / Service Bulletin
– 13AUG99)
– “Four Cylinder” Slide-Out
mi9549

SEAL INFORMATION

Click to Link
“Environmental” Seal Information (Air Seal & Wiper/Bulb Seal) ml44100bx_seal.html
“Hydraulic” Seal Replacement
– “Room Extension” Cylinders
mi1583

SNAP RING INFORMATION

Click to Link
Snap Ring Replacement Procedure
– “Train Drive” Slide-Out
mi15400c

STOP PAD & BEARING PLATE INFORMATION

Click to Link
• Installation Instructions
– Stop Plate & Bearing Pad Kit
– “Guided” Slide-Out System
mi15005h

SWITCH INFORMATION

Click to Link
• Pressure Switches on “Four Cylinder” Slide-Outs (Product / Service Bulletin
– 26APR2002)
– Room Operation with Synchronizing Cylinder Pressure Switches Unplugged
mi95400k
• Force Activated Switch
– Electrical Connection Diagram
– “Slimline” Slide-Outs
mi15991

VALVE INFORMATION

Click to Link
Check Valve Information
• Slide-Out Manifold Check Valve Replacement Instructions mi154750
Rack Sensing Valve
• Rack Sensing Valve
– Trouble Shooting, Replacement & Adjustment (mi1553 & mi1554)
ml10687
• Rack Sensing Valve
– Replacement & Adjustment
MP459420
Solenoid Valve Information
• Product / Service Bulletin
– Hydraulic Solenoid Valve I.D. & Replacement
mi957603
• Hydraulic Solenoid Valve
– Replacement of Two Soleniod Valves for Slide-Out Systems
mi159502
• Hydraulic Solenoid Valve
– Identification
– Manual Operation
– Replacement
– Manual Valve Release Instructions
MP849999

SALES MATERIAL

Click to Link
• Web Link: Slide-Out Home Page (Brochures & Videos) ml56900_so.html
• Talking Points
– “Universal Straight-Out (USO)” vs “X-Slide” Slide-Out
ml55893
• Features & Benefits of HWH® Slide-Outs ml23034c