► Operator Information – EMERGENCY MANUAL OPERATION ► Slide-Out Identification & Room Style (A/B) ► Adjustment Information ► Chain Link / Roller Information ► Control Panel / Control Box Information ► Control Unit (aka Manifold Assembly) Information ► Cylinder Information ► Diagnostics Information (Flow Charts) ► Electrical Information ► Hose Information ► Hydraulic Diagrams (Connection / Flow / Schematic) ► Installation & Pre-Installation Information ► Operator Information – EMERGENCY MANUAL OPERATION ► Operation Information – Normal Operation ► Performance Issues (Creeping, etc.) ► Pump & Power Unit Information ► Relay Information ► Seal Information (Hydraulic Seals & Environmental Seals) ► Snap Ring Information ► Stop Pad & Bearing Plate Information ► Switch Information (Pressure / Force-Activated / etc.) ► Valve Information (Solenoid Valve, Rack Sensing Valve, Check Valve, etc.) ► Sales Material (Brochures & Videos) | |||
SLIDE-OUT IDENTIFICATION & STYLE |
|||
• System Identification (Pictorial & Nomenclature) plus Link to Brochures & Videos |
ML17785_01_NOM_PR.HTML | ||
• System Styles (Type A/B Identification) | mi158331 | ||
ADJUSTMENT INFORMATION |
|||
• Room Adjustment – “Lateral Arm” Slide-Out Systems – “Lateral Arm with Torsional Tube” Slide-Out |
mi152002 | ||
• Room Adjustment – “Vertical Arm” Slide-Out |
ML18751 | ||
• Room Adjustment – “X-Slide” Slide-Out |
mi154560 | ||
• Room Adjustment (Product / Service Bulletin – 11OCT14) – “X-Slide” Slide-Out – 2004 Winnebago® Motorhomes |
mi9556 | ||
CHAIN LINK / ROLLER INFORMATION |
|||
• Chain Link / Roller Replacement – Locating Solenoid Valves (mi150068) – Disassembly & Assembly (mi150069) – “X-Slide” Slide-Outs – “Universal – (USO) (ULO) (UPLO) ( ULI/ULO)” Slide-Outs (All slide-out systems that start with “Universal") |
ml36149 | ||
• Roller Replacement Location Identification – X-Slide – Lateral Arm – Universal |
mi15535c | ||
CONTROL PANEL / CONTROL BOX INFORMATION |
|||
• Control Panel – Templates/Cut-Outs |
ml44100b1_ctrlpnl.html | ||
• Control Panel (for Slide-Outs) – Electrical Connection Diagram |
mp840500 | ||
• Weather Resistant Switch Box – Installation Instructions |
mi159412 | ||
CONTROL UNIT (aka Manifold Assembly) INFORMATION |
|||
• Control Unit Electrical Connection Diagram – Room 1 – Room 2 – Room 3 |
mp840400 | ||
CYLINDER INFORMATION |
|||
“Synchronizing” Cylinders | |||
• Synchronizing Cylinder Synchronizing Procedure – for Setup/Repair of Slide-Outs with Synchronizing Cylinders |
ml39247 | ||
• Synchronizing Cylinder Replacement Procedure – for ALL Slide-Outs with Two Cylinders and a Synchronizing Cylinder – includes Hose Assembly Replacement Procedure |
ML21970 | ||
• Bleeding Procedure for Remote Manifolds and/or Synchronizing Cylinders with Valving. | Mi9564 | ||
• “Synchronizing” Cylinder – Synchronizing/Bleed Procedure – for “Universal Straight-Out Light Duty (USOLD)” Slide-Out – Remote Manifold – Synchronizing Cylinders with Valving |
ml51267 | ||
• Synchronizing Cylinder Replacement – for “Universal Platform Level Out (UPLO)" – with Synchronizing Cylinder with Solenoid Valves |
ML57137 mp445001 mp445501 | ||
Cylinders | |||
• Cylinder – Seal Replacement Instructions |
MI1583 | ||
• Cylinder Replacement – for “Four Cylinder” Slide-Out |
ML21058 | ||
• Cylinder Replacement – for “Four Cylinder” Slide-Out – No Leveling System / Reversible Pump |
ML18759 | ||
• Cylinder Replacement/Bleeding Instructions – for “Four Cylinder” Slide-Out – No Leveling System / Reversible Pump |
ML18781 | ||
• Cylinder Replacement – for “Guided” Slide-Out with Special Washers |
mi15200j | ||
• Cylinder – Replacement Instructions – for “Guided” Slide-Out with Room Extension Manifold |
ML19524 | ||
• Cylinder Replacement – for “Lateral Arm” Slide-Out |
ML30248 | ||
• Cylinder Replacement – for “Level-Out (LO)” Slide-Out (Old name: “Flat Floor") |
ML23518 | ||
• Cylinder Replacement – for “Rail with HWH® Rack Sensing Valve” Slide-Out |
MP459415 | ||
• Cylinder – Replacement Instructions – for “Rail with HWH® Synchronizing Cylinder” Slide-Out |
ML16463 | ||
• Cylinder Replacement – for “Rail with HWH® Synchronizing Cylinder” Slide-Out – No Leveling System / Reversible Pump |
ML19241 | ||
• Cylinder Replacement – for “Single Cylinder” Slide-Out |
MP459412 | ||
• Cylinder Replacement – for “Train Drive” Slide-Out |
ML23527 | ||
• Cylinder Replacement – for “Universal Platform Level Out (UPLO)” Slide-Out – with Synchronizing Cylinder with Solenoid Valves |
ML57135 | ||
• Cylinder Replacement – for “Vertical Arm” Slide-Out |
ML18750 | ||
• Cylinder Replacement – for “Vertical Arm” Slide-Out – No Leveling System / Reversible Pump |
ML18702 | ||
DIAGNOSTICS INFORMATION |
|||
• Trouble-Shooting Flow Chart – Chinook RV Trail Wagons® Slide-Out Functions (HWH® 2000 Series) |
Page 1 of 2 mi957290 Page 2 of 2 mi957291 | ||
ELECTRICAL INFORMATION |
|||
• General Electrical Connection Protection | ml44100b1_elec.html | ||
HOSE INFORMATION |
|||
• Hose General Information (Swaging,Tightening, Warranties & Returns) | ml44100b1_hose.html | ||
• Hose Swage Leaks (Product / Service Bulletin – 12FEB03) – HWH® Slide-Out Systems |
mi9551 | ||
• Hose Swage Leaks – (Product / Service Bulletin – 06FEB03) – HWH® / Winnebago® Slide-Outs |
mi9550 | ||
HYDRAULIC DIAGRAMS (Connection / Flow / Schematic) | |||
Generic & OEM-Specific Diagrams | ml56050.html | ||
• Hydraulic Line Connection Diagram – Slide-Out Room Extension Connections at Manifold |
mp648490 | ||
• Hydraulic Line Connection Diagram – “Universal Level-In/Level-Out (ULI/ULO)” Slide-Out |
mp648325 | ||
• Hydraulic Line Connection Diagram – “Universal Level-Out (ULO)” Slide-Out |
mp648301 | ||
• Hydraulic Line Connection Diagram – “Universal Platform Level-Out (UPLO)” Slide-Out |
mp648325 | ||
• Hydraulic Line Connection Diagram – “Universal Straight-Out (USO)” Slide-Out |
mp648290 | ||
Generic Hydraulic Line Connection Diagrams | |||
BECAUSE THERE CAN BE CHANGES TO SYSTEM COMPONENTS, DRAWINGS LISTED HERE MAY DIFFER FROM EXISTING EQUIPMENT ON A PARTICULAR VEHICLE. IF NECESSARY, CONTACT HWH CORPORATION FOR ASSISTANCE. | (See also genericdiagrams3.html) | ||
“Guided” | ML50388 | ||
“In Floor” | ML50390 | ||
“Rail” | ML50389 | ||
Single cylinder | ML50387 | ||
“Universal Straight-Out (USO) | ML50391 | ||
“Universal Straight-Out Light Duty (OSOLD) | ML50392 | ||
“Universal Level-Out (ULO) with Room Lift Cylinders | ML50393 | ||
“Universal Level-Out (ULO) with Room Lift cylinders & Center Lift Cylinders | ML50394 | ||
“Universal Platform Level-Out (UPLO) with one Platform Lift Cylinder | ML50395 | ||
“Universal Platform Level-Out (UPLO) with two Platform Lift Cylinders | ML50529 | ||
“Universal Platform Level-Out (UPLO)” with three platform lift cylinders | ML50530 | ||
“Universal Platform Level-Out (UPLO)” with synchronizing cylinder box and three platform lift cylinders | ML50531 | ||
“Universal Level-In/Level-Out (ULI/ULO)” with one floor lift cylinder | ML50532 | ||
Manifold hydraulic connection diagram – 2 power extend/power retract jacks – 2 room extensions – auxiliary hand pump |
MP642470 | ||
INSTALLATION & PRE-INSTALLATION INFORMATION | |||
• Pre-Installation Information – CAUTION Maximum Hose Length Chart for Synchronizing Cylinder Systems |
Under Construction | ||
• Installation Video – “Universal Level-Out (ULO)” Slide-Out |
ml32486b.wmv | ||
• Installation Video – “Universal Level-Out (ULO)” Slide-Out |
ml32486c.wmv | ||
OPERATION INFORMATION – NORMAL OPERATION | |||
• Operator Manuals | ml44100b0_op_mls.html | ||
• “Rail with Rack Sensing Valve” Slide-Out (aka Newell® Phantom Suite®) |
mi150010 | ||
OPERATION INFORMATION – EMERGENCY MANUAL OPERATION | |||
• Manual Slide-Out Operation – General Information |
MP349490 | ||
• Hand-Pump Slide-Out System Operation (ML49509) | MP349907 | ||
• Hand-Pump System Priming Procedure | MP440015 | ||
• Slide-Out (Room or Generator) – Pump/Manifold with Solenoid Valves – Nut Release or Flipper Cam Release Valves – Manual Retraction Winch |
MP349500 | ||
• Slide-Out (Room or Generator) – Pump/Manifold with Solenoid Valves w/T-Handle Valve Release – Manual Retraction Winch |
MP359490 | ||
• Slide-Out (Room or Generator) – Reversible Pump with Emergency Retract Valve w/T-Handle Valve Release – Retract Tube – Manual Retraction Winch |
MP359440 | ||
• Slide-Out (Room or Generator) – Reversible Pump with Emergency Retract Valve – Manual Retraction Winch |
MP359472 | ||
• Slide-Out (Room or Generator) – Synchronizing Cylinder with Integrated Solenoid Valve Manifold – ________________ Release Valves – Manual Retraction Winch |
MP349498 | ||
• “Level Out ______________” Slide-Out – Pump/Manifold with Small (1.5" DIA) Solenoid Valves – Nut Release or Flipper/Cam Release Valves – Manual Retraction Bolt |
MP349553 | ||
• “Rail with HWH® Rack Sensing Valve” Slide-Out – WITHOUT ROOM RETRACTION WINCH. |
MP359410 | ||
• “Straight-Out or Level Out (Angle Mount) ______” Slide-Out – Pump/Manifold with Small (1.5" DIA) Solenoid Valves – Nut Release or Flipper/Cam Release Valves – Manual Retraction Bolt |
MP349551 | ||
• “Universal Level In/Level Out (ULI/ULO)” Slide-Out PG 1– MANUAL FLOOR LIFT PROCEDURE PG 2– MANUAL SLIDE-OUT RETRACT PROCEDURE – No Slide-Out Locks – One Set of Valves for the Floor-Lift and Slide-Out Located on the Pump/Manifold – Nut Release or Flipper/Cam Release Valves – Floor-Lift: Square Torsion Shaft – Slide-Out: Threaded Retraction Rods |
ML49809 mp349573 mp349574 | ||
• “Universal Level In/Level Out (ULI/ULO)” Slide-Out PG 1– MANUAL FLOOR LIFT PROCEDURE PG 2– MANUAL SLIDE-OUT RETRACT PROCEDURE – No Slide-Out Locks – One Set of Valves for the Floor-Lift and Slide-Out Located on Pump/Manifold – Nut Release or Flipper/Cam Release Valves – Floor-Lift: Splined Torsion Shaft – Slide-Out: Threaded Retraction Rods |
ML49810 mp349575 mp349576 | ||
• “Universal Level In/Level Out (ULI/ULO)” Slide-Out PG 1– MANUAL FLOOR LIFT PROCEDURE PG 2– MANUAL SLIDE-OUT RETRACT PROCEDURE – No Slide-Out Locks – One Set of Valves for the Floor-Lift and Slide-Out Located on Synchronizing Cylinder – Floor-Lift: Splined Torsion Shaft – Slide-Out: Threaded Retraction Rods |
ML52671 mp349575a mp349576a | ||
• “Universal Level Out (ULO)” Slide-Out System PG 1– MANUAL SLIDE-OUT PLATFORM LIFT PROCEDURE PG 2– MANUAL SLIDE-OUT RETRACT PROCEDURE – Small Solenoid Valves Located on Pump/Manifold – Nut Release or Flipper/Cam Release Valves – Platform-Lift: Manual Lift Bolts – Slide-Out: Threaded Retraction Rods |
ML36687 mp34956c mp34956d | ||
• “Universal Level Out (ULO)” Slide-Out |
ML54108 mp349563 mp349564 | ||
• One “Universal Level Out (ULO)” Slide-Out WITH JACKS PG 1– MANUAL JACK OPERATION PG 2– MANUAL SLIDE-OUT OPERATION – Pump Run Toggle Switch |
ml46786 mi953603 mi953604 | ||
• Two “Universal Level Out (ULO)” Slide-Outs WITH JACKS PG 1– MANUAL JACK OPERATION PG 2– MANUAL SLIDE-OUT OPERATION – Pump Run Toggle Switch |
ml46787 mi953605 mi953606 | ||
• Three “Universal Level Out (ULO)” Slide-Outs WITH JACKS PG 1– MANUAL JACK OPERATION PG 2– MANUAL SLIDE-OUT OPERATION – Pump Run Toggle Switch |
ml46788 mi953607 mi953608 | ||
• Four “Universal Level Out (ULO)” Slide-Outs WITH JACKS PG 1 – MANUAL JACK OPERATION PG 2 – MANUAL SLIDE-OUT OPERATION – Pump Run Toggle Switch |
ml46789 mi953609 mi953610 | ||
• “Universal Platform Level-Out (UPLO)” (EARLY STYLE) Slide-Out PG 1 – MANUAL SLIDE-OUT PLATFORM LIFT PROCEDURE PG 2 – MANUAL SLIDE-OUT RETRACT PROCEDURE – Small Solenoid Valves Located on Slide-Out Control Manifold – Nut Release or Flipper/Cam Release Valves – Platform-Lift: Manual Lift Bolts – Slide-Out: Threaded Retraction Rods |
ml49443 mp349559a mp349561a | ||
• “Universal Platform Level Out (UPLO)” (CURRENT STYLE) Slide-Out PG 1 – MANUAL SLIDE-OUT PLATFORM LIFT PROCEDURE PG 2 – MANUAL SLIDE-OUT RETRACT PROCEDURE – Small Solenoid Valves Located on Slide-Out Control Manifold Located on Synchronizing Cylinder – Flipper/Cam Release Valves – Platform-Lift: Manual Lift Bolts – Slide-Out: Threaded Retraction Rods |
ML52670 mp349559b mp349561b | ||
• “Universal Straight Out” (EARLY STYLE) Slide-Out – Small Solenoid Valves – Nut Release or Flipper/Cam Release Valves – Threaded Retraction Rods |
MP349556 | ||
• “Universal Straight Out” (CURRENT STYLE) Slide-Out – Small Solenoid Valves – Nut Release or Flipper/Cam Release Valves – Threaded Retraction Rods |
MP349558 | ||
• “Universal Straight Out” (CURRENT STYLE) Slide-Out – Small Solenoid Valves Located on Synchronizing Cylinder – Flipper/Cam Release Valves – Threaded Retraction Rods |
MP349580A | ||
• “X-Slide” Slide-Out – Small Solenoid Valves Located on Pump/Manifold – Nut Release or Flipper/Cam Release Valves – Threaded Retract Rods |
MP349554 | ||
• “X-Slide” Slide-Out – Reversible Pump with Emergency Retract Valve & Retract Tube – Threaded Retraction Rods |
MP35954C | ||
PERFORMANCE ISSUES (Creeping) |
|||
• Product / Service Bulletin (28AUG95) – Creeping – Diagnosing Slide-Out Rooms “Creeping” Issues – Type “A” Slide-Outs with Large Solenoid Valves |
mi9546 | ||
• Test Procedures for Room Cylinder Creep (MI158330/8331) | ml42737 | ||
PUMP & POWER UNIT INFORMATION |
|||
• General Pump & Power Unit Information | ml44100b1_pwrunit.html | ||
RELAY INFORMATION |
|||
• Relay Connections – Pump & Safety Relay Electrical Connections |
mp840450 | ||
• Relay Re-Wiring (Product / Service Bulletin – 13AUG99) – “Four Cylinder” Slide-Out |
mi9549 | ||
SEAL INFORMATION |
|||
“Environmental” Seal Information (Air Seal & Wiper/Bulb Seal) | ml44100bx_seal.html | ||
“Hydraulic” Seal Replacement – “Room Extension” Cylinders |
mi1583 | ||
SNAP RING INFORMATION |
|||
Snap Ring Replacement Procedure – “Train Drive” Slide-Out |
mi15400c | ||
STOP PAD & BEARING PLATE INFORMATION |
|||
• Installation Instructions – Stop Plate & Bearing Pad Kit – “Guided” Slide-Out System |
mi15005h | ||
SWITCH INFORMATION |
|||
• Pressure Switches on “Four Cylinder” Slide-Outs (Product / Service Bulletin – 26APR2002) – Room Operation with Synchronizing Cylinder Pressure Switches Unplugged |
mi95400k | ||
• Force Activated Switch – Electrical Connection Diagram – “Slimline” Slide-Outs |
mi15991 | ||
VALVE INFORMATION |
|||
Check Valve Information | |||
• Slide-Out Manifold Check Valve Replacement Instructions | mi154750 | ||
Rack Sensing Valve | |||
• Rack Sensing Valve – Trouble Shooting, Replacement & Adjustment (mi1553 & mi1554) |
ml10687 | ||
• Rack Sensing Valve – Replacement & Adjustment |
MP459420 | ||
Solenoid Valve Information | |||
• Product / Service Bulletin – Hydraulic Solenoid Valve I.D. & Replacement |
mi957603 | ||
• Hydraulic Solenoid Valve – Replacement of Two Soleniod Valves for Slide-Out Systems |
mi159502 | ||
• Hydraulic Solenoid Valve – Identification – Manual Operation – Replacement – Manual Valve Release Instructions |
MP849999 | ||
SALES MATERIAL |
|||
• Web Link: Slide-Out Home Page (Brochures & Videos) | ml56900_so.html | ||
• Talking Points – “Universal Straight-Out (USO)” vs “X-Slide” Slide-Out |
ml55893 | ||
• Features & Benefits of HWH® Slide-Outs | ml23034c |
EMERGENCY
SLIDE-OUT RETRACTION
(ROOMS, GENERATORS, STORAGE COMPARTMENTS)
ML44100BX_SO