- BATTERIES & GROUNDS
- CAPACITOR / VOLTAGE STABILIZATION KITS
- CONNECTIONS & CONNECTORS
- RELAYS (for High-Current Use)
- SWITCH – LIMIT SWITCH
- SWITCH – NEUTRAL HOLD
- SWITCH – PRESSURE SWITCH
- SWITCH – REED SWITCH
- SWITCH – RESET SWITCH
- SWITCH – SWITCH INTERFACE INFORMATION
- SWITCH – WARNING SWITCH
- WARNING LIGHT/BUZZER
- WIRE ADAPTERS & UPDATES
- WIRE NUMBER STANDARDS
BATTERIES & GROUNDS | Click to Link | |
Battery Voltage and Grounds (Product / Service Bulletin) | MI9545 | |
Ground Enhancement Instructions (Product / Service Bulletin) ~ for 610 Non-Central Ground Leveling Systems ~ Includes pump, control box, and warning switch grounding instructions. |
ML10906 | |
Ground Enhancement Instructions ~ for Fenner Stone Power Units with 3" Diameter Motors. |
ML10906 | |
CAPACITOR / VOLTAGE STABILIZATION KITS | Click to Link | |
Capacity / Voltage Stabilization – Central Control Module – LDV / 4D Security Vehicles | MI154575 | |
CONNECTIONS & CONNECTORS | Click to Link | |
Protection of Electrical Connections | MI9554 | |
32 Pin Detsch® Strike Connector Plug Module 32A ~ Used on 700/725 Series I/O Modules ~ How to Assemble & Disassemble the 32-Pin Strike Plug |
Strike_Plug_How_To | |
Replacement of 1-Wire Components with 2-Wire Components ~ Valves, Switches, Etc. |
MI1551 | |
RELAYS (for High-Current Use) | Click to Link | |
Relays – Identifying Features | mi15191 | |
Product/Service Bulletin • Newmar 2007 Essex and Newmar Mountain Aires Built January 2006 thru July 2006 • Master Relay Rotation with Installation of Adapter Plate Kit RAP91917 |
MI9557 | |
Leveling System (______ Series) “Master” Relay – Wiring Diagram • ______ Series, Computer-Control (Touch Panel-Control) |
MI152011 | |
Leveling System (610 Series) “Master & Pump” Relay – Wiring Diagram • 610 Series, Computer-Control |
MP855042 | |
Leveling System (610/625/725/2000 Series) “Master & Pump” Relay – Wiring Diagram • 610 Series, Computer-Control Central Ground • 625 Series • 725 Series • 2000 Series |
MI152010 | |
Leveling System (610 Series) “Master & Pump” Relay – Wiring Diagram • 610 Series, Computer-Control with 4.5″ Motors OBSOLETE |
OBSOLETE – MI1577 | |
Leveling System (400 Series) “Master & Pump” Relay – Wiring Diagram • 400 Series, Computer-Control (Paddle Switch Control) |
MI152013 | |
Leveling System “Pump” Relay – Wiring Diagram • Lever-Control & Touch Panel-Control |
MI152012 | |
Leveling System (100/100 – 200 Series) “Pump” Relay – Wiring Diagram • 100/110 Series Four Lever-Control • 200 Series Joystick-Control |
MI1518 | |
Leveling System “Master & Pump” Relay – Wiring Diagram • Alternate Grounding 4.50″ Motors |
MI1519 | |
Leveling System “Master & Pump” Relay – Wiring Diagram • Alternate Grounding 3.00″ Motors with Ground Stud |
MI1501 | |
SWITCH – SWITCH INTERFACE INFORMATION | Click to Link | |
Jack (Straight-Acting 16K & 24K) Switch Interface (AP9072) – Warning/Pressure Switch – Connection Diagram • 16K & 24K Straight-Acting Jack Cylinder Replacement • Convert Cylinder with 1-Wire Warning Switch • 610 Series Non-Central Ground Systems |
MI1580 | |
Jack (Straight-Acting – 16K & 24K) Switch Interface (AP9072) – Warning/Pressure Switch – Instruction Sheet • 16K & 24K Straight-Acting Jack Cylinder Replacement • Convert Cylinder with 1-Wire Warning Switch to Cylinder with 2-Wire Magnetic Warning Switch • 610 Series Non-Central Ground Systems |
MI154754 | |
SWITCH – LIMIT SWITCH | Click to Link | |
Slide-Out TRAVEL CLAMP Limit Switch – Replacement Instructions | MI15400R | |
SWITCH – NEUTRAL HOLD | Click to Link | |
Switch Assembly – Neutral Hold – Removal / Installation Instructions • for RAP91824 (AP22748) Switch Assembly Neutral Hold |
MI15400R | |
SWITCH – PRESSURE SWITCH | Click to Link | |
Product/Service Bulletin – Adjustment for All Jack Pressure Switches • Jack Pressure Switch Adjustment for 610/625/625S, 725 & 2000 Series Leveling Systems |
MI9544 | |
Jack Pressure Switch Installation • All Jacks (Generic) |
MI352009 | |
Jack Pressure Switch Installation – Straight-Acting Jack – 6K – AP37148 • AP37148 Jack Assembly |
MI1599 | |
Jack Pressure Switch Installation – Kick-Down Jack – 9K • 9K Kick-Down Jacks (Pressure Switch on Back Side) (MI1507 – OBSOLETE) |
MI912276 | |
Jack Pressure Switch Installation – Straight-Acting Jack – 4K/6K • Dodge Sprinter Rear S/A Jacks (4K AP37942) & (6K AP37542) |
MI152008 | |
Jack Pressure Switch Installation – Straight-Acting Jack – 4K • 4,000 lb. Straight-Acting Jack with Pressure Switch Window in Pivot Bracket |
MI152102 | |
Leveling System Manifold Pressure Switch Installation • 3500 PSI Pressure Switch • Leveling System Manifold |
ML47649 | |
MI154572 | ||
MI154573 | ||
Slide-Out Pressure Switch (Force-Activated Switch) – Electrical Connection Diagram • “Slimline” Slide-Out Room Cylinder Force-Activated Switch Assembly and Information |
MI15991 | |
Slide-Out Pressure Switch – Product/Service Bulletin • Synchronizing Cylinder “Four-Cylinder” Slide-Out Pressure Switches • Four-Cylinder Slide-Out Room Extension Systems |
MI95400K | |
SWITCH – REED | Click to Link | |
Reed Switch Assembly (AP16731) Handling Instructions – (for Slide-Out Room Locks) | MI15005C | |
Reed Switch Assembly (AP19246) Handling Instructions – (for Slide-Out Room Locks) | MI15005E | |
SWITCH – RESET | Click to Link | |
Lighted Reset Switch Installation | MI15600C | |
SWITCH – WARNING SWITCH | Click to Link | |
Warning Switch – Parts Manual | mr50.html | |
Jack Warning Switch – Installation – AP28804/AP28803 | MI15100J | |
Jack Warning Switch (or Control Box) Grounding Instructions for Jack | MI1513 | |
Jack (Kick-Down) Warning Switch Interface – Replacement Instructions • 3-Wire “Tilt” Warning Switch for Kick-Down Jacks • Harness with 1-Pin Packard or One 2-Pin Packard |
MI154756 | |
Jack (Kick-Down) Warning Switch – Two-Wire – Replacement Instructions | MI1503 | |
Jack (Kick-Down – 06K) 1-Wire Warning Switch – Connection Diagram • for All Manual Leveling Systems with 2-Wire Warning Switch |
MP653040 | |
Jack (Kick-Down – 09K) 2-Wire Warning Switch -Connection Diagram • for All Manual Leveling Systems with 2-Wire Warning Switch |
MP653045 | |
Jack (Kick-Down – 16K) Warning Switch – 2-Wire – Connection Diagram • for all Manual Leveling Systems with 2-Wire Warning Switch |
MP653030 | |
Jack (Straight-Acting) Warning Switch Adapter – 1-Wire to 2-Wire – AP92382 Adapter Kit – Instruction Sheet • Adapter Kit for 1-Wire Warning Switches • Replace 1-Wire Warning Switch with 2-Wire Warning Switch • Gray or Black 2-Pin Packard Connector |
MI156033 | |
Jack (Straight-Acting) Warning Switch – Interface – Replacement Instructions • 3-Wire “Magnetic” Warning Switch for Straight-Acting Jacks • Harness with 1-Wire and 1-Pin Packard or Two Wires with 2-Pin Packard |
MI154757 | |
Jack (Straight-Acting) Warning Switch – 2-Wire – with Black Packard Connector – Replacement Instructions | MI1504 | |
Jack (Straight-Acting) Warning Switch – 2-Wire – Connection Diagram • Straight-Acting Jacks (with Side/Side Return Springs) on all Manual Leveling Systems with 2-Wire Warning Switch |
MP653035 | |
WARNING LIGHT/BUZZER | Click to Link | |
Jacks Down Warning Light and Buzzer – Product/Service Bulletin • 310 & 610 Series Leveling Systems |
MI95400C | |
Master Warning Light/Buzzer Connection Diagram • Manual Leveling Systems |
MI1578 | |
Master Warning Light/Buzzer Connection Diagram • _____________ Leveling Systems OBSOLETE |
OBSOLETE – MI1579 | |
WIRE ADAPTERS & UPDATES | Click to Link | |
OBSOLETE – Installation Instructions for Replacement Parts with 2-Wire Packard Connectors with AP1403 Adapter Wire | OBSOLETE – mi1551 | |
Adapter Kit for Single-Wire Warning Switches – RAP44005 (AP44005) Instruction Sheet | mi156033 | |
Pigtail Update For 625 Single-Touch Leveling System with Remote Rocker Switches | mi1598 | |
WIRE NUMBER STANDARDS | Click to Link | |
Wire Number Standards | MI94250D |