- Label hose directly across from the LR jack solenoid of what jack extended.
- Open the left front (LF) jack solenoid.
- Push the pump run switch and extend the jack 1-2".
- Close the LF solenoid before releasing the pump run switch.
- Label hose directly across from the LF jack solenoid of what jack extended if different than the LF jack.
- Open the right front (RF) jack solenoid.
- Push the pump run switch and extend the jack 1-2".
- Close the RF solenoid before releasing the pump run switch.
- Label hose directly across from the RF jack solenoid of what jack extended if different than the RF jack.
- Open the right rear (RR) jack solenoid.
- Push the pump run switch and extend the jack 1-2".
- Close the RR solenoid before releasing the pump run switch.
- Label hose directly across from the RR jack solenoid of what jack extended if different than the RR jack.
- Open all solenoid valves and retract jacks.
- With all jacks fully retracted move labeled hoses to correct ports shown on diagram.
- Loosen/Tighten hoses per instructions found here.
|
All jacks are plumbed correctly.
Restart test. |
No jack extendsFile: VALVE RELEASE LEVER IS LOOSE WITH VALVE IN CLOSED POSITION.doc and then return to this page. |